material - aluminium PA 11 that has the following features:
high corrosion resistance also in sea and industry enviroment
high tensile strength
high fatigue resistance
almost three times lower weight than made of the same thickness steel S235
The aluminium is powder coated in high temperature in the color RAL7035.
Designed to:
mount on pole (by using a dedicated bracket ID 2520) or to the wall (surface mounting)
be used when constructing electric, telecommunication and fiber optic installations, in order to:
protect devices from harmful influence of external factors (water, dust, oil ect.) and unauthorized access of third parties and destruction by them,
arrange the devices and provide appropriate working conditions for the devices.
Standard equipment:
roof of the cabinet moved forward to cover the door top
profiled one leaf door:
protecting the seal from outside interference
opened on right side
locked with a one point lock with an EURO LOCK key
profiled door leaf to press the seal
polymer seal that has:
high resistance to ozone, oxidation and acid
low deformation level
working temperature from -29 up to +66 C degrees
two bolt hinges
6U high RACK profiles mounted 70mm from the front wall which can be moved 10mm further into the cabinet
four mounting holes in the back part of the cabinet
marked out holes in the floor of the cabinet
2 holes fi 23mm
1 hole fi 16mm
Construction of the cabinet allows to:
open the doors 180degrees
dismantling the doors without any tools only in the position 180 degrees
drainage and preventing water penetration thanks to:
roof of the cabinet moved forward to cover the door top and secured joint "roof-door" to secure from precipitation
special profiled door leaf that presses the seal (this is especially important when the temperature is below 0C degrees)
water and dust tightness - protection level IP 55
protection from mechanical impact - protection level IK 10
grounding mounted in cabinet.
ATTENTION - If there are mounted electrical devices in the cabinet, the cabinet must be grounded. For grounding use a tape or wire minimum fi 6mm2. In order to secure the grounding from self-loosening use a tooth lock washer between the fixture and nut.
Product specification:
Height
Width
Depth
Weight
Lock
Material
Holes to PG21 gland
Holes to PG16 gland
Tightness
402mm
330mm
230mm
3kg
lock with a single point locking with an EURO LOCK key
aluminium PA11
2pcs
1pcs
IP 55
Download:
Karta Katalogowa
CE Deklaracja Zgodności
Technical assistance
When you buy a product in our store, you get free access to:
technical support for purchased products,
and help in the hardware configuration,
get a product inspected and tested by our experts,
Our website uses cookies (ie. Cookies) for statistical, advertising and functional. Thanks to them, we can customize the site to your needs. Anyone can accept cookies, or has the ability to disable them in your browser, so you will not collect any information.